Leakrate housing |
1.10 E-10 mbar.l/s |
|||
| Pressure range | Vacuum to 2 bar abs | |||
| Differential pressure at valve plate |
1 bar in any direction | |||
| Differential pressure during opening |
1 bar in any direction |
|||
| Lifetime until first
service: Temperature range: Housing Plate gasket Actuator Materials: Housing Plate gasket Bonnet flange gasket Mechanism (outside vacuum) |
5,000,000 250°C 200°C 200°C |
|||
| 1.4435 Viton Viton Steel, aluminium |
||||
Subject to change